Vol. 20 Núm. 1
Hugo Villarroel-Ábrego¹*, Dra. Elaine Núñez², Raúl Garillo³
1. Médico internista, cardiólogo ecocardiografista, Facultad de Medicina, Universidad Salvadoreña “Alberto Masferrer” (U.S.A.M.), Hospital de Diagnóstico Escalón, San Salvador, El Salvador.
2. Médico electrofisióloga, Centros de Diagnóstico y Medicina Avanzada y de Conferencias Médicas y Telemedicina (CEDIMAT), Santo Domingo, República Dominicana.
3. Médico cardiólogo universitario. Profesor adjunto de Fisiología, Facultad de Ciencias Médicas, Pontificia Universidad Católica Argentina.Buenos Aires, República Argentina.
* Correspondencia: Dr. Hugo Villarroel-Ábrego. Villavicencio Plaza, Segundo Nivel, Local No. 12, Colonia Escalón, San Salvador, El Salvador, Centro América. E-mail: h_villarroel@yahoo.com
Métricas
21
Visualizaciones
Compartir
Compartir
Resumen (ES)
Se presenta el caso de un varón de 56 años con cardiomiopatía no compactada y muy severa disfunción ventricular, con trastorno de conducción intraventricular y QRS ancho. Adolecía de comorbilidades incluyendo nefropatía diabética terminal (en diálisis) y nunca pudo recibir terapia médica óptima por hipotensión e hiperkalemia. Con indicación IIa para terapia de resincronización cardíaca se le implantó resincronizador con desfibrilador, con respuesta aguda clínica y ecocardiográfica excelente. Falleció a los tres meses del implante por asistolia que no pudo ser rescatada por el dispositivo. Es nuestra opinión que la presencia de comorbilidades graves y la imposibilidad de dar terapia médica óptima son una limitante para el éxito a mediano y largo plazo de la terapia de resincronización.
Palabras clave: Terapia de resincronización cardíaca. Cardiomiopatía no compactada. Trastorno de conducción intraventricular.
Resumen (EN)
We present the case of a 56-year-old man with non-compaction cardiomyopathy and very severe ventricular dysfunction, with intraventricular conduction disorder and wide QRS. He suffered from comorbidities including terminal diabetic nephropathy (on dialysis) and was never able to receive optimal medical therapy for hypotension and hyperkalemia. With indication IIa for cardiac resynchronization therapy, a resynchronizer with a defibrillator was implanted, with an acute clinical and excellent echocardiographic response. He died three months after the implant due to asystole that could not be rescued by the device. It is our opinion that the presence of severe comorbidities and the impossibility of giving optimal medical therapy are a limitation for the medium and long-term success of the resynchronization therapy.
Key words: Cardiac resynchronization therapy. Non-compaction cardiomyopathy. Nonspecific intraventricular conduction delay.
Explorar
Artículos
Volúmenes
Sobre la revista
Más leídos
Revista Costarricense de Cardiología
Consenso costarricense para el manejo integral de la diabetes mellitus, abordaje metabólico cardiorrenal
Revista Costarricense de Cardiología
Revista Costarricense de Cardiología
¿Cuál es la realidad centroamericana y del Caribe en torno a la cardiopatía isquémica?
Revista Costarricense de Cardiología
Revista Costarricense de Cardiología